Fire Resistant Power Cable is specially designed to maintain power transmission during a fire. It ensures the continuity of power supply to emergency circuits, such as fire pumps, alarms, lighting, ventilation systems, and emergency exits. The cable uses fire-resistant materials and special insulation to guarantee reliable operation under extreme heat or flame exposure.


- Conductor: Annealed copper, Class 1 or Class 2, according to IEC 60228.
- Insulation: Mica tape wrapped fire-resistant layer + XLPE or PVC insulation.
- Inner Sheath: PVC or LSZH (Low Smoke Zero Halogen) compound.
- Armour (optional): Steel Wire Armour (SWA) or Steel Tape Armour (STA).
- Outer Sheath: PVC or LSZH, available in red, orange, or customized colors.
- Voltage Grade: 0.6/1kV or as required.


Technical Specifications
|
Item |
Description |
|
Rated Voltage |
0.6/1kV |
|
Conductor Material |
Annealed Copper |
|
Insulation Material |
Mica Tape + XLPE/PVC |
|
Sheath Material |
PVC / LSZH |
|
Fire Resistance Standard |
IEC 60331 / BS 6387 (CWZ) |
|
Smoke Density |
IEC 61034-2 |
|
Halogen Acid Gas Emission |
IEC 60754-1/2 |
|
Temperature Range |
-15°C to +90°C |
|
Test Voltage |
3.5 kV/5 min |
|
Flame Retardancy |
IEC 60332-3 compliant |
|
Type |
Description |
Application occasion |
|
|
Cu |
Al |
||
|
NH-YJV |
NH-YJLV |
Cross-linked polyethylene insulated polyvinyl chloride sheathed fire-resistant power cable |
To be laid indoors, in the tunnel, cable furrow, pipe or under soft soil. The cable can not bear mech- anical force from outside. Single core cable isn't permitted to be laid in the magnetic pipe. |
|
NH-YJY |
NH-YJLY |
Cross-linked polyethylene insulated polyethylene sheathed fire-resistant power cable |
|
|
NH-YJV22 |
NH-YJLV22 |
Cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed fire-resistant power cable |
To be laid underground (depth of burying: at least 0.7m above earth), the cable can bear certain mechanical force, but it can not beart great pulling force. |
|
NH-YJV23 |
NH-YJLV23 |
Cross-linked polyethylene insulated steel tape armored polyethylene sheathed fire-resistant power cable |
|
Features & Benefits
- Maintains circuit integrity under fire for at least 90–180 minutes
- Low smoke, halogen-free, and environmentally safe
- Excellent flame retardant and heat resistance performance
- Resistant to mechanical stress and oil
- Suitable for indoor or outdoor installation
- Ensures safe evacuation and protection of critical systems during fire emergencies
Applications
- Emergency power and lighting systems
- Fire alarm and control circuits
- High-rise buildings and public infrastructure
- Metro, tunnels, airports, and hospitals
- Power plants and industrial control systems








Standards
Complies with:
- IEC 60331
- BS 6387
- IEC 60332
- IEC 60502
- GB/T 19666
- VDE 0482








Hot Tags: fire resistant power cable, China fire resistant power cable manufacturers, suppliers, factory, Fire Resistant Power Cable, Low Voltage Power Cable, power cable, Silicone Rubber Power Cable, Special Power Cable, XLPE Fire Resistant Cable