Product Overview
Low Smoke Zero Halogen Data Cable is intended for low-voltage data and signal transmission in electrical and electronic equipment where fire-safety requirements are higher than those of conventional PVC cables.
The cable combines Class 5 stranded bare copper conductors, halogen-free core insulation, and a low-smoke zero-halogen outer sheath. Its compact construction helps save installation space, while the sheath and insulation materials are designed to limit smoke density and corrosive gas generation during fire exposure.
Rated at 300 V, the cable is suitable for computer systems, measuring equipment, control devices, office equipment, and other signal transmission applications.
Cable Structure
Typical construction:
Class 5 Copper Conductor → Halogen-Free Core Insulation → LSZH Outer Sheath
Class 5 Copper Conductor
Multi-strand bare copper conductors comply with IEC 60228 Class 5, providing flexibility for routing and installation.
Halogen-Free Core Insulation
Special halogen-free compound insulation provides electrical insulation while supporting low-smoke and low-corrosive-gas performance.
LSZH Outer Sheath
The outer sheath uses a special low-smoke zero-halogen compound and is supplied in Grey (RAL 7001) as standard.
Technical Data
| Parameter | Specification |
|---|---|
| Rated Voltage | 300 V |
| Conductor | Multi-Strand Bare Copper |
| Conductor Class | IEC 60228 Class 5 |
| Core Identification | DIN 47100 Color Coding |
| Insulation | Halogen-Free Compound |
| Outer Sheath | Low Smoke Zero Halogen Compound |
| Standard Sheath Color | Grey (RAL 7001) |
| Insulation Resistance | >20 MΩ·km |
| Test Voltage | 1500 V |
| Capacitance | Approx. 100 nF/km |
| Inductance | Approx. 0.65 mH/km |
| Fixed Temperature Range | -30°C to +80°C |
| Occasional Movement Temperature | -5°C to +70°C |
| Fixed Bending Radius | 7.5 × Cable Diameter |
| Occasional Movement Bending Radius | 15 × Cable Diameter |
Fire Safety Performance
Flame Retardant
The cable is specified to comply with IEC 60332-1-2 for flame propagation performance.
01
Halogen-Free
The cable complies with IEC 60754-1 requirements for halogen acid gas content.
02
Low Corrosive Gas Emission
The material system is specified to comply with EN 50267-2-3 for acidity and corrosive gas performance.
03
Low Smoke Density
The cable complies with IEC 61034-2 for low smoke emission.
04
In fire conditions, this combination helps reduce smoke generation and corrosive gas release compared with conventional halogen-containing cable materials.
Why Choose LSZH for Data Cabling?
For many signal and data installations, electrical performance is only part of the selection criteria.
In buildings or equipment areas with high personnel density or valuable assets, cable material behavior during fire can also be important.
This LSZH construction is suitable where buyers are concerned about:
- Smoke visibility during fire
- Halogen acid gas generation
- Corrosive gas exposure
- Damage to sensitive equipment
- Fire-safety requirements in occupied environments
Compact Design for Limited Installation Space
The cable is designed with a relatively small overall diameter, helping reduce space requirements in:
- Control cabinets
- Electronic equipment
- Cable ducts
- Measuring devices
- Compact machinery
- Office and building systems
Its construction also provides good stripping performance for installation and termination.
Typical Applications
Computer and Electronic Systems
Suitable for low-voltage data and signal connections in computer-related and electronic equipment.
Measuring Equipment
Used for signal transmission between measuring devices, instruments, and electronic control units.
Control Systems
Can be used in low-voltage control and monitoring circuits where LSZH cable materials are preferred.
Office and Building Equipment
Suitable for installations where compact routing and low-smoke halogen-free materials are required.
High-Occupancy Areas
Applicable to environments where reducing smoke and corrosive gas emissions during fire is an important design consideration.
Sensitive Equipment Areas
Suitable for locations containing valuable electronic or measurement equipment where corrosive fire gases are undesirable.
Installation Guidance
For installation:
- Maintain a minimum bending radius of 7.5 × cable diameter for fixed installation.
- Maintain a minimum bending radius of 15 × cable diameter for occasional movement.
- Avoid excessive tensile force during installation.
- Prevent sharp bending or crushing.
- Keep the cable within the specified operating temperature range.
- Confirm voltage and signal requirements before cable selection.
This cable is intended for fixed installation and occasional movement, rather than continuous high-cycle drag-chain operation.
Standards
| Standard | Related Requirement |
|---|---|
| IEC 60228 Class 5 | Flexible copper conductor construction |
| IEC 60332-1-2 | Flame propagation performance |
| IEC 60754-1 | Halogen acid gas content |
| EN 50267-2-3 | Acidity / corrosive gas performance |
| IEC 61034-2 | Smoke density |
| DIN 47100 | Core color identification |
FAQ
Need an LSZH Data Cable for Your Project?
Please send us:
Core Count + Cable Length + Voltage + Installation Condition + Required Standard + Quantity
We can help confirm the suitable low-smoke zero-halogen data cable configuration for your application.