Product Overview
PVC Sheathed Control Cable For Drag Chain is intended for control and signal circuits in machinery and automation systems where cables are repeatedly bent during operation.
The cable combines ultra-fine stranded Class 6 copper conductors, TPE core insulation, non-woven fabric wrapping, and a PVC outer sheath. This construction provides the flexibility and mechanical durability required for repeated movement inside cable drag chains.
With a rated voltage of 300/500 V, a mobile operating temperature range of -5°C to +70°C, and a minimum moving bending radius of 7.5 × cable diameter, it is suitable for demanding industrial motion applications.
Product Identification
| Item | Specification |
|---|---|
| Product Type | Drag Chain Control Cable |
| Rated Voltage | 300/500 V |
| Conductor | Ultra-fine Stranded Bare Copper |
| Conductor Class | IEC 60228 Class 6 |
| Core Insulation | TPE |
| Wrapping | Non-Woven Fabric |
| Outer Sheath | PVC |
| Sheath Color | Grey (RAL 7001) |
| Drag Chain Life | Approx. 10–15 Million Cycles |
| Fixed Temperature Range | -40°C to +70°C |
| Mobile Temperature Range | -5°C to +70°C |
| Minimum Bending Radius – Fixed | 4 × Cable Diameter |
| Minimum Bending Radius – Mobile | 7.5 × Cable Diameter |
Cable Construction
Typical cable construction:
Ultra-Fine Copper Conductor → TPE Insulation → Stranded Core Assembly → Non-Woven Fabric Wrapping → PVC Outer Sheath
Ultra-Fine Copper Conductor
The conductor uses ultra-fine stranded bare copper compliant with IEC 60228 Class 6, helping reduce mechanical stress during repeated bending.
01
TPE Core Insulation
Flexible TPE insulation supports repeated movement while maintaining electrical insulation between individual conductors.
02
Stranded Core Assembly
The insulated cores are stranded together to form a flexible cable assembly suitable for repeated reciprocating motion.
03
Non-Woven Fabric Wrapping
The non-woven wrapping helps maintain the cable structure while allowing the cores to move during repeated bending.
04
PVC Outer Sheath
The PVC outer sheath provides wear resistance and a relatively low-friction surface for movement inside cable drag chains.
05
Technical Data
| Technical Parameter | Specification |
|---|---|
| Core Identification | DIN VDE 0293, black cores with white numerical identification |
| Conductor Resistance | Complies with IEC 60228 Class 6 |
| Rated Voltage | 300/500 V |
| Insulation Resistance | >20 MΩ·km |
| Test Voltage | 2000 V |
| Protective Earth Core | G = with yellow/green protective conductor; X = without protective conductor |
| Temperature Range – Fixed Installation | -40°C to +70°C |
| Temperature Range – Mobile Installation | -5°C to +70°C |
| Minimum Bending Radius – Fixed Installation | 4 × Cable Diameter |
| Minimum Bending Radius – Mobile Installation | 7.5 × Cable Diameter |
| Drag Chain Life | Approx. 10–15 Million Cycles |
Applicable Standards
| Standard | Application |
|---|---|
| IEC 60228 Class 6 | Flexible conductor construction |
| IEC 60332-1-2 | Flame propagation / flame-retardant performance |
| EN 50290-2-22 (TM54) | Oil resistance of sheath material |
| DIN VDE 0293 | Core identification |
Key Performance
The cable is designed for approximately 10–15 million drag chain cycles under suitable installation and operating conditions.
Actual service life may vary depending on:
- Bending radius
- Travel distance
- Movement speed
- Acceleration
- Cable load
- Drag chain layout
- Ambient temperature
The ultra-fine stranded Class 6 conductor provides improved flexibility compared with conventional fixed-installation conductors and is suitable for repeated bending.
The PVC sheath is specified for oil resistance according to EN 50290-2-22 (TM54), making it suitable for industrial environments where machine oil or lubricants may be present.
The cable complies with IEC 60332-1-2 flame propagation requirements.
The relatively smooth PVC sheath helps reduce friction during repeated movement inside cable drag chains.
Available Configurations
| Cores × Cross Section | Outer Diameter (mm) | Copper Weight (kg/km) | Cable Weight (kg/km) |
|---|---|---|---|
| 2 × 0.5 mm² | 5.5 | 9.5 | 36 |
| 3G0.5 mm² | 5.8 | 14.2 | 45 |
| 4G0.5 mm² | 6.2 | 19.0 | 54 |
| 5G0.5 mm² | 6.8 | 23.7 | 65 |
| 6G0.5 mm² | 7.5 | 28.5 | 79 |
| 7G0.5 mm² | 8.0 | 33.2 | 90 |
| 8G0.5 mm² | 8.8 | 38.0 | 106 |
| 10G0.5 mm² | 9.7 | 47.5 | 127 |
| 12G0.5 mm² | 10.0 | 57.0 | 144 |
| 14G0.5 mm² | 10.7 | 66.4 | 167 |
| 15G0.5 mm² | 11.1 | 71.2 | 182 |
| 16G0.5 mm² | 11.4 | 75.9 | 190 |
| 18G0.5 mm² | 12.1 | 85.4 | 219 |
G indicates that the cable includes a yellow/green protective earth conductor.
Other configurations can be supplied according to project requirements.
Applications
CNC Machinery
Suitable for electrical control and signal circuits in CNC machines where cables repeatedly move with machine axes and moving assemblies.
01
Automated Production Lines
Used for control wiring in automated production equipment requiring frequent reciprocating cable movement.
02
Conveying and Handling Systems
Suitable for conveyors, transfer systems, and material handling equipment using cable drag chains.
03
Packaging Machinery
Can be used in packaging and processing machinery where control cables repeatedly bend during normal operation.
04
Machine Tools and Moving Equipment
Applicable to moving electrical control systems where cable flexibility and repeated bending performance are required.
05
Installation Conditions
For drag chain applications:
- Maintain a minimum bending radius of 7.5 × cable diameter during movement.
- Avoid twisting the cable during installation.
- Do not apply excessive tensile force.
- Leave sufficient free space inside the drag chain.
- Avoid overfilling the drag chain.
- Install cables so they can move freely without crossing or binding.
- Observe the specified operating temperature range.
- Select the cable according to travel distance, movement speed, acceleration, and required cycle life.
Customization Options
Available configurations may include:
- Number of cores
- Conductor cross-section
- G or X core configuration
- Outer sheath color
- Cable marking
- Cable length
- Packaging length
- Customer-specific identification
Manufacturing Process
Typical production flow:
Copper Stranding → TPE Insulation → Core Cabling → Non-Woven Wrapping → PVC Sheathing → Cable Marking → Electrical Testing → Final Inspection → Packaging
Actual production processes should follow the confirmed cable specification and factory manufacturing requirements.
Quality Control
Typical inspection items may include:
- Conductor resistance
- Insulation resistance
- Voltage test
- Cable outer diameter
- Core identification
- Sheath appearance
- Cable marking
- Dimensional inspection
- Flexing performance, where applicable
For drag chain applications, supporting test information may also include:
- Drag chain cycle testing
- Bending testing
- Oil resistance testing
- Voltage testing
- Outer diameter inspection
Ordering Information
When requesting a quotation, please provide:
- Number of cores
- Conductor cross-section
- G or X configuration
- Required cable length
- Drag chain travel distance
- Movement speed
- Bending radius
- Required cycle life
- Operating temperature
- Applicable standard
- Quantity
- Packaging requirements
For drag chain applications, providing the travel distance, movement speed, bending radius, and required cycle life helps us confirm a more suitable cable configuration.
Hot Tags: pvc sheathed control cable for drag chain, China pvc sheathed control cable for drag chain manufacturers, suppliers, factory